- “Felicity Solar 10kva 8kw Off Grid inverter” already exists in your wishlist
Automatic UPS switching10 second 200 Percent surge power backup overload capability
Supports 1ph and 3ph flexible connection with max 36kW in parallel
Up to 135A max charge/discharge current
6 customizable charge/discharge time settings
Compatible with lead-acid and lithium batteries, with multiple battery protection features
Supports peak shaving control in both “self-use” and “generator” mode
Generator connectivity with multiple input methods and automatic generator On/Of control
Specifications
Input DC (PV side)
Recommended max. PV power: 8 kW
Max. input voltage: 600 V
Rated voltage: 330 V
Start-up voltage: 90 V
MPPT voltage range: 90-520 V
Max. input current: 16 A / 16 A
Max. short circuit current: 24 A / 24 A
MPPT number/Max. input strings number: 2/2
Battery
Battery type: Li-ion / Lead-acid
Battery voltage range: 40-60 V
Max. charge / discharge power: 5 kW
Max. charge / discharge current: 112 A
Communication: CAN/RS485
Output AC (Grid side)
Rated output power: 5 kW
Max. apparent output power: 5.5 kVA
Operation phase: 1/N/PE
Rated grid voltage: 220 V / 230 V
Rated grid frequency: 50 Hz / 60 Hz
Rated grid output current: 22.7 A / 21.7 A
Max. output current: 25 A
Power factor: >0.99 (0.8 leading – 0.8 lagging)
THDi: <2 Percent
Input AC (Grid side)
Input voltage range: 187-253 V
Max. input current: 32 A
Frequency range: 45-55 Hz / 55-65 Hz
Output AC (Back-up)
Rated output power: 5 kW
Max. apparent output power: 2 times of rated power, 10 s
Back-up switch time: <4 ms
Rated output voltage: 1/N/PE, 220 V / 230 V
Rated frequency: 50 Hz / 60 Hz
Rated output current: 22.7 A / 21.7
Max. output current: 32 A
Max. AC Passthrough current: 40 A
THDv (@linear load): <2 Percent
Efficiency
Max. efficiency: > 97.5 Percent
EU efficiency: > 96.2 Percent
Protection
DC reverse-polarity protection: Yes
Ground fault monitoring: Yes
Integrated AFCI (DC arc-fault circuit protection): Yes
Protection class/Over voltage category: I/II
General Data
Dimensions (W*H*D): 406*560*205 mm
Weight 24 kg
Topology: High frequency isolation (for battery)
Operating ambient temperature range: -40 ~ +60°C
Ingress protection: IP66
Cooling concept:Natural convection
Max. operation altitude: 4000 m
Grid connection standard: NRS 097-2-1, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA
Safety/EMC standard: IEC/EN 62109-1/-2, EN 61000-6-2/-3
Features
DC connection: MC4 plug (PV port) / Terminal Block (BAT port)
AC connection: Terminal Block
Display: LED + APP
Communication: RS485, CAN, Optional: Wi-Fi, GPRS, LAN